[SG36CX-P2] Sungrow Inverter 36kW, Max.PV input voltage 1,100V(DC), 4 MPPT 3 Phase
SG36CX-P2
Recommended max. PV input power 50.4 kWp
Max. PV input voltage 1100 V
Min. PV input voltage / Startup input voltage 160V / 200V
36kW, Max.PV input voltage 1,100V(DC), 4 MPPT 3 Phase
Recommended max. PV input power 70 kWp
Max. PV input voltage 1100 V
Min. PV input voltage / Startup input voltage 160V / 200V
Rated PV input voltage 600V
MPP voltage range 160V-1000V
No. of independent MPP inputs 4
No. of PV strings per MPPT 2
Max. PV input current 120 A ( 30 A * 4 )
Max. DC short-circuit current 160 A ( 40 A * 4 )
Max. current for DC connector 30 A
Output (AC)
Rated AC output power 36 kW (415 V @50°C) *
Max. AC output apparent power 40 kVA (415 V @40°C) *
Max. AC output current 60.2 A
Rated AC output current( at 230V ) 52.17 A
Rated AC voltage 3 / N / PE, 220 V / 380 V, 230 V / 400 V
AC voltage range 312 V - 480 V
Rated grid frequency 50 Hz / 60 Hz
Grid frequency range 45 Hz – 55 Hz / 55 Hz – 65 Hz
Harmonic ( THD ) < 3 % ( at rated power )
Power factor at rated power / Adjustable power factor > 0.99 / 0.8 leading – 0.8 lagging
Feed-in phases / AC connection 3 / 3-N-PE
fficiency
Max. efficiency / European efficiency 98.5% / 98.3%
Protection
Grid monitoring /Yes
DC reverse polarity protection /Yes
AC short-circuit protection /Yes
Leakage current protection /Yes
Surge protection /DC Type I+II / AC Type II
Ground fault monitoring /Yes
DC switch /Yes
PV String current monitoring /Yes
Arc fault circuit interrupter (AFCI) /Yes
PID recovery function /Yes
Optimizer compatibility * /Optional
General Data
Dimensions (W*H*D) 645 mm * 575 mm * 245 mm
Weight 40 kg
Mounting Method Wall-mounting bracket
Topology Transformerless
Degree of protection IP66
Night power consumption < 5 W
Corrosion C5
Operating ambient temperature range -30 ℃ - 60 ℃
Allowable relative humidity range (non-condensing) 0 % - 100 %
Cooling method Smart forced air cooling
Max. operating altitude 4000 m
Display LED, Bluetooth+APP
Communication RS485 / Optional: WLAN, Ethernet
DC connection type Evo2 ( Max. 6 mm² )
AC connection type OT terminal (16 - 35 mm²)
AC Cable specification Outside diameter 18 mm - 38 mm mm²)
Grid Compliance IEC 62109, IEC 61727, IEC 62116, VDE-AR-N 4105:2018, IEC 61000-6-3, EN 50549- 1, CEI 0-21 2019,CEI0-16 2019, VDE 0126-1-1/A1 VFR 2019, UTE C15-712-1:2013, UNE 206007-1/RD 1699, UNE 217002, G99,IEC 63027
Grid Support Q at night function, LVRT, HVRT,active & reactive power control and power ramp rate control