logo mammoth energy svg

MANUFACTURER: Sofar

P/N : 5KTLM-G3

5KTLM-G3
Recommended max. PV input power 7500Wp
Max. DC power for single MPPT 3750W
Number of MPP trackers 2
Number of DC inputs 1 for each MPPT
Max. input voltage 600V
Start-up voltage 90V
Rated input voltage 380V
MPPT operating voltage range 80V-550V
Full power MPPT voltage range 210V-500V

 


Contact Sales สอบถามราคาพิเศษเพิ่มเติม ได้ที่::

ฝ่ายขาย ADD LINE : @emthailand
Phone  095-675-8034

support2

    S gainfriends 2dbarcodes GW  เพิ่มเพื่อน

Sofar 5Y:

การรับประกันสินค้า 5 ปี

5KW 1 Phase
Recommended max. PV input power 7500Wp
Max. DC power for single MPPT 3750W
Number of MPP trackers 2
Number of DC inputs 1 for each MPPT
Max. input voltage 600V
Start-up voltage 90V
Rated input voltage 380V
MPPT operating voltage range 80V-550V
Full power MPPT voltage range 210V-500V
Max. input MPPT current 15A / 15A
Max. input short circuit current per MPPT 22.5A / 22.5A
Output (AC)
Rated power 5000W
Max. AC power 5500VA 
Nominal output current 22.7A
Max. output current 25A
Nominal grid voltage L / N / PE, 220Vac, 230Vac, 240Vac
Grid voltage range 180Vac-276Vac (according to local standard)
Nominal frequency 50Hz / 60Hz
Grid frequency range 45Hz-55Hz / 54Hz-66Hz (according to local standard)
Active power adjustable range 0...100%
THDi < 3%
Power factor 1 default (adjustable + / -0.8)
Max. efficiency 98.4%
European efficiency 97.5%
DC reverse polarity protection Yes
DC switch Optinal
AFCI protection Optinal
Protection class / overvoltage category I / III
Safety protection Anti islanding, RCMU, Ground fault monitoring
SPD MOV: Type III standard
Standard communication mode RS485 / USB, Optional: WiFi / GPRS
Ambient temperature range 30℃...+60℃
Self-consumption at night < 1W
Topology Transformerless
Degree of protection IP65
Allowable relative humidity range 0...100%
Max. operating altitude 4000m
Noise <25dB
Weight 10Kg
Cooling Natural
Dimension 349*344*164mm
Display LCD, App via Bluetooth
Standard warranty 5 years, optional: 7 & 10 years
EMC EN 61000-6-2, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12 
Safety standards IEC62109-1 / 2, IEC62116, IEC61727, IEC-61683, IEC60068 (1, 2, 14, 30)
Grid standards VDE-AR-N 4105, VDE V 0126-1-1, V 0124-100, AS / NZS 4777, CEI 0-21, G98 / G99, C10 / 11, EN 50549, RD 1699


1. ทางบริษัทฯ ขอสงวนสิทธิ์ในการรับผิดชอบใดๆ อันเนื่องจากข้อผิดพลาดทางการพิมพ์ (ผิด/ตก)

2. ทางบริษัทฯ ขอสงวนสิทธิ์ในการเปลี่ยนแปลงราคาและโปรโมชั่นโดยไม่แจ้งให้ทราบล่วงหน้า