logo mammoth energy svg

MANUFACTURER: Hoymiles

P/N : HYS-6.0LV-EUG1

HYS-6.0LV-EUG1
Battery type Li-ion/Lead-acid
Battery voltage range (V) 40-60
Max. charge/discharge current (A) 100/100
Max. charge/discharge power (W) 5000/5000 
Charging strategy for Li-ion battery Self-adaption to BMS
Charging curve 3 Stages/Equalization
External temperature sensor Optional
Communication CAN


Contact Sales สอบถามราคาพิเศษเพิ่มเติม ได้ที่::

ฝ่ายขาย ADD LINE : @emthailand
Phone  095-675-8034

support2

    S gainfriends 2dbarcodes GW  เพิ่มเพื่อน

Hoymiles 5Y:

การรับประกันสินค้า 5 ปี

Inverter 6kW 1 phase
Battery type Li-ion/Lead-acid
Battery voltage range (V) 40-60
Max. charge/discharge current (A) 100/100
Max. charge/discharge power (W) 5000/5000 
Charging strategy for Li-ion battery Self-adaption to BMS
Charging curve 3 Stages/Equalization
External temperature sensor Optional
Communication CAN
PV Input
Recommended max. PV power (W) 7500
Max. input voltage (V) 550
Rated voltage (V) 360
Start-up voltage (V) 150
MPPT voltage range (V) 125-500
Max. input current (A) 14/14
Max. short circuit current (A) 17/17
MPPT number/Max. input strings number 2/2
AC Input and Output (On-grid)
Rated output power (W) 6000
Max. output apparent power (VA) 6000
Max. input power (W) 7360
Grid form L/N/PE
Rated AC output voltage/Range (V) 230, 161-276
Rated grid frequency (Hz) 50/60
Max. output current (A) 26.0
Max. input current (A) 32.0
Power factor >0.99 (0.8 leading ... 0.8 lagging)
THDi (@rated output) <3% 
AC Output (Off-grid)
Rated output power (W) 6000
Max. output apparent power (VA) 10000, 10s
Back-up switch time (ms) <10
Grid form L/N/PE
Rated output voltage (V) 230
Rated output frequency (Hz) 50/60
Max. continuous output current (A) 26.0
THDv (@linear load) <3%
Efficiency
MPPT efficiency 99.9%
Max. efficiency 97.6%
EU efficiency 97.0%
Max. battery discharge to AC efficiency 95.0%
Protection
Anti-islanding protection Integrated
PV string input reverse polarity protection Integrated
Insulation resistor detection Integrated
Residual current monitoring unit Integrated
AC over current protection Integrated
AC short current protection Integrated
AC overvoltage and undervoltage protection Integrated
Surge protection DC Type II/AC Type III
General
Dimensions (W × H × D [mm]) 502 × 461 × 202
Weight (kg) 24
Mounting Wall mounting
Operating temperature (℃) -25 to +65 (>45, derating)
Relative humidity 0-95%, no condensing
Cooling Natural convection
Topology (Solar/Battery) Transformerless/High-frequency isolation
Altitude (m) ≤2000
Protection degree IP65
Noise (dB) <40
User interface LED, App
Digital input/output DRM, 1 × DI, 2 × DO
Communication RS485, optional: Wi-Fi/Ethernet/4G(4)
Certifications and Standards
Grid connection standard EN 50549, VDE-AR-N 4105, VFR: 2019, TOR Erzeuger Type A, RD647, NTS (SENP), CEI 0-21 2019:04, C10-11 Type A
Safety/EMC standard IEC 62109-1/-2, EN 61000-6-1/-3 


1. ทางบริษัทฯ ขอสงวนสิทธิ์ในการรับผิดชอบใดๆ อันเนื่องจากข้อผิดพลาดทางการพิมพ์ (ผิด/ตก)

2. ทางบริษัทฯ ขอสงวนสิทธิ์ในการเปลี่ยนแปลงราคาและโปรโมชั่นโดยไม่แจ้งให้ทราบล่วงหน้า