[SUN-60K-SG01HP3-EU-BM4] Deye 60KW/3phase, IP65 Battery Voltage range 160 -700V Free CT and Wifi
SUN-60K-SG01HP3-EU-BM4
Battery Type Lithium-ion
Battery Voltage Range (V) 160-1000
Max. Charging Current (A) 80+80
Max. Discharging Current (A) 80+80
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 2
60KW/3phase, IP65 Battery Voltage range 160 -700V Free CT and Wifi
Battery Type Lithium-ion
Battery Voltage Range (V) 160-1000
Max. Charging Current (A) 80+80
Max. Discharging Current (A) 80+80
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 2
Max. PV Access Power (W) 120000
Max. PV Input Power (W) 96000
Max. PV Input Voltage (V) 1000
Start-up Voltage (V) 180
MPPT Voltage Range (V) 150-850
Rated PV Input Voltage (V) 36+36+36+36+36+36
Max. Input Short-Circuit Current (A) 54+54+54+54+54+54
No. of MPP Trackers/ No. of Strings MPP Tracker 6/2+2+2+2+2+2
Rated AC Input/Output Active Power (W) 60000
Max. AC Input/Output Apparent Power (VA) 66000
Rated AC Input/Output Current (A) 91/87
Max. AC Input/Output Current (A) 100/95.7
Max. Continuous AC Passthrough (grid to load) (A) 200
Peak Power (off-grid) (W) 1.5 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form 3L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Max. Efficiency 97.60%
Euro Efficiency 97.0%
MPPT Efficiency >99%
Integrated DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level
Surge Protection Leve TYPE II(DC), TYPE II(AC)
Communication Interface RS485/RS232/CAN
Monitor Mode GPRS/WIFI/Bluetooth/4G/LAN(optional)
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 3000m
Noise (dB) ≤65
Ingress Protection(IP) Rating IP65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 606×927×314 (Excluding Connectors and Brackets)
Weight (kg) 97.5
Type of Cooling Intelligent Air Cooling
Warranty 5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2